Macey's Electrical Logo

Clare Instruments Logo

  Comprehensive Tester  

 

You are here:

 Clare G102 Tester Specifications
Navigation:  Clare Comprehensive Test Station Index > GENIUS/GENIUS LITE Index >
 
Clare G-Series of advanced, microprocessor controlled, comprehensive test stations, designed to meet both production line and type testing requirements. G102 GENIUS Lite
Standard comprehensive test station

Specifications/Measurement Functions
 

 
 
Phase Neutral Continuity Earth Bond

Test Voltage:

5V D.C.

Test Voltage:

7.5V A.C.

Acceptance Range:

10Ω to 1000Ω

Output Current Range:

5.0A to 25.0A settable in

Accuracy:

±2% ±2Ω

 

0.1A steps

Test Duration:

0.5s to 10.0s

Compliance Ranges:

0Ω to 150MΩ at 25A

Trip Level upper/lower:

10Ω to 1000Ω ±2% ±2Ω

 

0Ω to 500MΩ at 10A
   

Measurement Range MΩ:

0Ω to 1000MΩ ±2% ±1MΩ
AC/DC Flash

Measurement Range mV:

0 to 4000mV ±2% ±1mV

Test Voltage:

0 to 4.0kV in 10V steps

Test Duration:

0.5s to 10.0s
  0 to 5kV settable in

Trip Level upper/lower:

1Ω to 1000MΩ
  10V steps    

Class I output:

0 to 2.5kV DC Insulation Resistance Test

Class II output:

0 to 4kV

Test Voltage:

500V D.C.

Output Rating:

500VA

Trip Range:

2.0 to 500MΩ ±5% ±0.2MΩ

Waveform:

distortion less than 1%

Test Duration:

0.5s to 10.0s

Line/Load Regulation:

better than 1%    

Maximum Slew Rate:

10kV/s General Specifications

Ramp Timer (up/down):

0.5s to 10.0s

Operating Mode:

Automatic or Manual

Dwell Timer:

0.5s to 300.0s

Temperature:

storage: 0°C to +40°C

Leakage Trip Upper:

A.C.: 0.1mA to 10.0mA   operation: +10°C to +35°C
  in 0.1mA increments

Humidity:

95% max. non-condensing
  D.C.:0.1mA to 5.0mA

Dimensions:

370mm (L) x 185mm (H)
  in 0.1mA increments                      x 485mm (D)

Leakage Trip Lower:

A.C.: 0.1mA to 10.0mA

Weight:

24kg
  in 0.1mA increments    

*no test detection

D.C.:0.1mA to 5.0mA Options
  in 0.1mA increments

Alternative Supply:

110V A.C. operation

Trip Accuracy:

±2% of setting

3, 5, or 10 meter Cables:

RS232 cable
  ±0.5mA

Printer:

Star industrial label printer

Failure Mode:

breakdown and/or trip

High visibility beacon:

low voltage red/green

Failure Indication:

visual and audible

 

surface mounted
   

ENC Enclosures:

Testing enclosures
     
ARC Detection    
  detection circuit which    
  prevents damage to    
  device under test    

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008