Macey's Electrical Logo

Clare Instruments Logo

  G106 Production Line Tester

 

You are here:

 Model G106 Electrical Safety Tester
Navigation:  Clare Comprehensive Test Station Index >
 
 
The G106 Tester assists manufacturers to ensure their products continue to comply throughout the manufacturing process by providing a fully flexible test station.



 
G106
Electrical Safety Tester for production lines

Features

  • Ideal for fast and efficient production line operator control.
  • Supervisor programmable for manufacturer specific test sequences.
  • Results storage for total traceability and evidence of due diligence.
  • Compatible with barcode scanners, printers and other accessories, for faster testing.
  • Supplied with its own PC Software.
Description
The G106 Tester assists manufacturers to ensure their products continue to comply throughout the manufacturing process by providing a fully flexible test station. The microprocessor controlled tester conducts a series of pre-programmed tests and provides an indication of pass/fail.

Results are reordered in the units memory and can be downloaded to a printer or to PC software. Providing fast and effective testing the G106 can be operated individually or connected in series.

Connection Facilities
EUT Power output CEE Socket, Printer port RS232, Barcode RS232, Computer I/F RS232, Eight user voltage free change over relay contacts, eight user voltage free inputs, External start, External stop, Beacon Pass/Fail, Isolated analog 8 Bit recording channel and Audible warning output.

Standards

  • EN60950 Information Technology
  • EN61010 Measurement Control & Laboratory
  • EN60598 Luminaries
  • EN60065 Domestic Appliances
  • EN60335 Household Appliances
  • BS2769  Motorized Power Tools
Specifications
       
Earth Bond Test Continuity Test

Measuring Range:

10m to 20Ω, 1mΩ resolution

Test Voltage:

Nominal 6V rms

Test Voltage:

6 V rms nominal o/c

Test Current:

500mA programmable

Output Current:

6.0, 12.0, 25A nominal into s/c

Pass Range:

≤400mA

Pass Range:

Programmable in steps of 10mΩ

Time:

1 second

Time:

1 to 60 seconds programmable    
       
Earth Screen Test Operations Test

Measuring Range:

10m to 20Ω, 1mΩ resolution

Measuring Range:

0 to 4.0kV

Test Voltage:

100mV rms nominal o/c

Test Voltage:

Mains supply

Output Current:

100mA nominal into s/c

Pass Range:

High and low limit programmable

Pass Range:

0.1 to 2.0 programmable   in 0.1kVA steps

Time:

1 to 60 seconds programmable

Time:

1 to 60 seconds programmable
       
Insulation Test Leakage Test

Measuring Range:

0.1 to 300MΩ

Measuring Range:

0.1 to 99mA

Test Voltage:

500Vdc @ 500KΩ

Test Voltage:

Mains supply

Pass Range:

Programmable in steps of 1MΩ

Pass Range:

Programmable in steps of 0.1mA

Time:

1 to 60 seconds programmable

Increase Voltage:

User option to increase by 6%
      or 10%
   

Time:

1 to 60 seconds programmable
Flash Test/Hipot/Dielectric    

Measuring Range:

0.3 to 9.9mA General

Test Voltage:

1.5kV rms for Class I

Dimensions:

515mm x 175mm x 380mm
  0 to 5kV for Class II

Weight:

15kg
  via probe - programmable in    
  250V steps    

Pass Range:

Programmable in steps of 0.1mA    

Time:

1 to 60 seconds programmable    

 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 