  Comprehensive Tester  

 

You are here:

 Clare G2-GENIE
Navigation:  Clare Comprehensive Test Station Index >
 

Clare G2-GENIE Comprehensive Electrical Safety Tester Designed for production line use.

 
G2-GENIE
Comprehensive Electrical Safety Tester Designed for production line use.                      

Features

  • Earth Bond (Ground).
  • Hi-Pot (Flash) AC/DC.
  • Insulation Resistance.
  • Bar Code Reading of Test Configurations.
  • Multi Test Profile Storage.
  • Bi Direction Communications.
  • Manual or Fully Automated Tests.
AC Flash Specifications Insulation Resistance

Voltage Range:

0.100 ~ 5.000kV

DC Output Voltage:

250V, 500V or 1000V
            (programmable)   selectable, or fully adjustable

Voltage Resolution:

10V/step (settable)   from 10V to 1000V

Voltage Resolution:

10V/step (settable)

Resistance Ranges:

0.1Ω to 100.0MΩ

Voltage Accuracy:

1% of reading   100MΩ to 1GΩ

Max. Output Current:

20mA at 5kV

Resistance Accuracy:

0.1MΩ to 700MΩ 5% of

Current Range:

0.01 to 20mA   Reading - 700MΩ to 1GΩ

Current Resolution:

0.01mA

 

10% of reading

Current Accuracy:

1% of reading    
       
DC Flash Specifications

Earth Bond

Voltage Range:

0.100 ~ 6.000kV

Test Voltage:

Nominal 6V AC

Voltage Resolution:

10V/step (settable)

Output Current Range:

5.0A to 25A settable in 0.1A
      steps

Voltage Accuracy:

1% of reading

Compliance Ranges:

0 to 150mΩ at 25A

 

    0 to 500mΩ at 10A

Max. Output Current:

10mA at 6kV

Measurement Range m:

0 to 1000mΩ ±2% ±1mΩ

Current Range:

0.10 to 10mA 0.01mA

Measurement Range mV:

0 to 4000mV ±2% ±1mV

Current Resolution:

0.01mA

Test Duration:

0.5 second to 10.0 seconds

Current Accuracy:

1% of reading

Trip Level upper/lower:

1 to 1000mΩ

Output Ripple:

< 5% at 6kV    
   

Note: Results can be displayed as millivolts.

ARC Detection

         Four wire measurements for accurate reading

Detect Current:

10 levels          at the point of test, derived from a regulated
             a.c. voltage source.
 
 
Ordering Code
G201 G2-GENIE Super Combined Test Instrument
G201LS Lead set
 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008