Product Description
The 800PL Series DC hipot testers provide an economical solution to DC field testing of cables, terminations, motors, generators and other electrical apparatus. Models 815PL and 880PL offer 15kV or 80kV respectively. All models are self contained in a single rugged and durable enclosure which is complete from input line cord to high voltage output cable. Cables are conveniently stored inside the case.

The 800 Series testers feature accurate kV meter readings regardless of load current. Accurate voltage and current measurements are assured since voltage readings are taken directly at the output of the high voltage transformer and current measurements are taken in the return leg. Safe discharging of both the test object and the high voltage transformer occur whenever the high voltage is turned off. Output power is provided by means of a full-wave voltage doubling rectifier circuit with silicon rectifiers.
 

The 800PL series of DC Hipot Testers provide an economical solution to DC field testing of cables, terminations, motors, generators and other electrical apparatus.

 

 

Features
  • Rugged and portable.
  • One-piece construction.
  • Shielded output cable.
  • Guard circuit.
  • Full-wave voltage doubling rectifier circuit.
  • Zero start interlock.
  • Internal discharge on HV OFF.
  • Meter accuracy ± 2% full scale.
  • 5 mA current rating for cable charging.
  • External interlock provisions.
  • Three range voltmeter.
  • Four range current meter.
  • No internal leakage at full load.
  • Instantaneous overload relay.
  • Surge-limiting resistors in HV output.

Benefits
  • Ideal for field testing - lightweight, compact, and rugged.
  • Safe and easy operation.
  • No exposed high voltage.
  • Accurate leakage current measurement.
  • Guard circuit eliminates stray leakage currents.
Applications
DC Hipot testing of:
  • Cable.
  • Transformers.
  • Electrical Switchgear.
  • Motors.
  • Generators.
  • Other Electrical Apparatus.
Specifications
Model

815PL

880PL

Output Voltage

0 to 15kV

0 to 80kV

Output Current

5mA

5mA

Weight                               Net 47lb (21kg) 76lb (34kg)

Shipping

57lb (26kg) 86lb (39kg)
Polarity Negative output, positive ground
Metering

±2% full scale accuracy

Ripple

Less than 2.5%

Dimensions

18" (W) x 13" (D) x 13" (H)   (46mm (W) x 33mm (D) x 33mm (H)

Input Line Cord

6ft (1.8m) 3-wire and plug, ground type

Return Cable

25ft (7.6m)

High Voltage Output Cable

25ft (7.6m) shielded RG34/U w/alligator clip and rubber insulated boot

Note:
For Input Voltage of 120V/60Hz model number suffix -A  (e.g. model 880PL-A)
For Input Voltage of 220V/50Hz model number suffix -B  (e.g. model 880PL-B)
 
Accessories
Catalog No. Description
SPK1-815PL Spare Part Kits
SPK1-880PL Spare Part Kits
 
Click to View Panel Detail


 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008