MS-2 Circuit Breaker and Overload Relay
                                                 Test Set - Features

You are here:

MS-2 Features

Navigation:

High Current Tester Index >  Megger Product Index >   Specifications > Ordering Information
 
Product Features and Benefits
Model MS-2 is a self-contained test set that incorporates a variable high-current output and appropriate control circuitry and instrumentation for testing thermal, magnetic or solid-state motor overload relays; molded-case circuit breakers; and ground-fault trip devices.
  • Digital memory ammeter: High-accuracy, direct reading instrument has read-and-hold memory for measurement of
    short-duration currents.
     
  • Digital, multi-range timer: Crystal-controlled, high accuracy
    instrument with autoranging measures operating time to 1 millisecond.
     
  • High-current output: Provides instantaneous currents
    up to 750 amperes through a 125 ampere breaker.
     
  • Solid-state output initiate circuit: Solid-state circuit
    eliminates need for contact maintenance.
     
  • Portable, high-current test set: Unit weighs only 33 lb
    (15 kg) and is tough enough to withstand daily field or plant
    use.

 

Description
The MS-2 test set is used around the world by several thousand utility companies, industrial plants and electrical service organizations.

Using the latest technology, Model MS-2 is a self-contained test set that incorporates a variable high-current output and appropriate control circuitry and instrumentation for testing thermal, magnetic or solid-state motor overload relays; molded-case circuit breakers; and ground-fault trip devices.

 
 
Applications
Model MS-2 is capable of testing the time-delay characteristics of motor overload relays and molded-case
circuit breakers rated up to 125 amperes, when following the recommended test procedure of testing the time delay of these devices at three times their rating.

Higher currents are available for the short durations required to test an instantaneous trip element. For example, the test set will provide a maximum short duration output of 750 amperes through a typical, 125 ampere, molded-case circuit breaker.

Additional applications include verifying the ratio of current transformers and testing panel-board ammeters and
voltmeters.

 
Click to View Specifications

 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008