OTS/VCM100

  • Allows a quick check of high voltage output to be made.

  • Tests up to 100 kV with accuracy of 3%.

  • Easy to read mirror arc display with tolerance bands.

Operation
The OTSAF/2 series are programmed with a test sequence suitable for using the VCM100 called ‘CHECK CALIBRATION’. This sequence causes the output of the oil test set to ramp up from 0 kV to the maximum voltage value, pausing at each 10 kV point for 10 seconds to allow the calibration to be checked.

Other versions of Megger oil test sets (such as the OTSAF, OTS60 auto and OTS75 auto) can be used in manual mode or with a low rate of voltage rise to allow checking with the VCM100. Later versions of the OTSAF also have the ‘CHECK CALIBRATION’ procedure.






 

  VCM100
AVO/Megger VCM100 Calibration Meter.
 

Specification

Panel Meter scaling

0 to 100 kV in 2 kV divisions

Accuracy

±3% of full scale

 

 

Temperature Range

Operating

0°C to 40°C

Storage

-30°C to 70°C

 

 

Humidity Range

Operating

80% RH at 40°C

Storage

93% RH at 40°C

 

 

Safety

The meter is only approved for

 

use with Megger oil test sets

Dimensions

198mm x 235mm x 102mm

 

 

Weight

2.4 kg

  AVO/Megger VCM100 Scale Plate.
OTS VCM100 Scale Plate
 
   
Parameters of test specifications (programmed in OTS60PB, OTS60AF/2, OTS80AF/2 and OTS100AF/2) Maximum Duration of Selected Test
Sequence
Test Spec Selected Electrode Shape Initial Stand Rate of rise of test voltage Intermediate Stir Time Intermediate Stand Time Number of Tests

OTS60B
OTS60AF/2

OTS80AF/2 OTS100AF/2
5 min test B 1 minute 2kV/sec 30 sec 30 sec 3 4 min. 30s 5 minutes 5 min 30s
IEC156 etc A, B 5 minutes 2kV/sec 2 minutes
option 1
2 minutes
option 2
6 18 minutes 19 minutes 20 minutes
ASTM D877 C 2 min 20sec 3kV/sec - 1 minute 5 8 minutes 8 min 33sec 9 min 7sec
ASTM D1816 A 3 minutes 0-5kV/sec continuous 1 minute 5 17 minutes 20 min 20s 23 min 40s
UNE21 A, B 10 minutes 2kV/sec 1 minute 4 minutes 6 38 minutes 39 minutes 40 minutes
Withstand A B 0 -99 min
55 sec**
2kV/sec Ramps to pre-selected value of 1 minute or breakdown
Withstand B B 0 -99 min
55 sec**
2kV/sec As above and continues to breakdown or maximum value of test set
Custom
(1-5)*
- 0 -99 min
55 sec**
0,5 - 5,0 kV/s*
0 to 99 min 55s* 0 to 99 min 55s* 1 to 99
- - -
BS5730A   A, B - 2kV/sec 1 minute 1 minute Withstand test at 22kV, 30kV or 40kV (depending on equipment category and electrode gap) for 60 sec. If breakdown occurs another two tests are carried out, both must pass if sample is OK.
 
Note: * User selectable
Note: ** OTSAF/2 only
   
IEC156 etc. includes BS148, BS5874, VDE 0370, NFC 27, CE1344, OCT 6581, SABS555, AS1767, STA8286 and IP295.
 
NFC27, STAS286 and UNE21 omit the first breakdown value from the average calculation.
 
STAS286 has a 2 minute intermediate stand time

 

AVO/Megger OTS60PB Automatic Oil Tester.
OTS60PB
 Automatic oil tester
 

   

AVO/Megger OTS100AF/2 Automatic Oil Tester.
OTS60AF/2, OTS80AF/2, OTS100AF/2
Automatic oil testers
 

Models OTS60PB OTS60AF/2, OTS80AF/2, and OTS100AF/2
Features



 
  • Powered by internal, rechargeable battery.
  • Fully automatic operation.
  • Pass/fail limit setting.
  • Automatic laboratory set.
  • Built in printer and RS232 output.
  • Custom test facility.

 

Test Voltage






 
60 kV maximum (30 kV - 0 - 30 kV)






 
OTS60AF/2:60 kV maximum
(30 kV - 0 - 30 kV) @ 61,8 Hz.

OTS80AF/2:80 kV maximum
(40 kV - 0 - 40 kV)

OTS100AF/2:100 kV maximum
(50 kV - 0 - 50 kV)

Power Supply






 
Internal, rechargeable 12 V, 12 Ah battery
(giving typically 12 hours continuous use)

Charger supply 85 to 265 V, 50/60 Hz

Optional 12 V supply lead enables operation from vehicle cigarette lighter socket

110 V, 120 V, 220 V, 240 V ±10%
50/60 Hz

Four pre-selectable values



 

Display Dot matrix LCD giving alphanumeric information and kV test voltage.
Resolution  1Kv 1kV
Dimensions 373mm (H) x 259mm (W) x 247mm (D) 464mm (H) x 502mm (W) x 319mm (D)
Weight 19kg 41kg
Fuses





 
2 x F6,3 A, IEC127/1, 20 mm x 5 mm, HBC





 
2 x F6,3 A, IEC127/1, 20 mm x 5 mm, HBC

T2 A, IEC127/5, 20 mm x 5 mm, HBC for 220/240 V

T4 A, IEC127/5, 20 mm x 5 mm, HBC for 110/120 V
Temperature Range

Storage

0°C to 40°C 0°C to 40°C

Operating

-30°C to +65°C -40°C to +70°C
Humidity Range

Storage

93% RH at 40°C, 95% RH at 25°C cyclic 93% RH at 40°C, 95% RH at 25°C

Operating

80% RH at 40°C 80% RH at 40°C
Safety




 
Designed to incorporate where appropriate

IEC1010-1, safety class I.

Safety interlock to BS5304 (1988) ‘Guarding of Machinery’ standard.

Meets the requirements of IEC1010-1 (1991)

Safety interlock to BS5304 (1988) ‘Guarding of Machinery’ standard.
 

Other




 
RS232 output plus optional printer kit

Includes battery charger and four test
Option to set pass/fail breakdown values.

 

RS232C 5 pin DIN socket

Five custom tests allowing; 1 to 99 tests
0,5 to 5 kV/s rate of voltage rise
0 to 99 min. 59 s stir and stand times
Averaging start from first to last test

 
Printer Information
  The OTS60PB Printer kit includes a 24 column impact printer with integral rechargeable batteries and mains adapter which operates from 85V to 265 V AC 50/60Hz. The printer measures 105mm x 195mm x 90mm and weighs 625g.


 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008