 Transformer Ohmmeter Test Set Specifications
Navigation:  Transformer Testing Equipment Index > Megger Product Index
   Transformer Ohmmeter Features/Description Transformer Ohmmeter Ordering Details >
 
Specifications    
       
Measuring Principle

Environmental

  Electronic Thompson-type circuit   Operating:
      32 to 104° F (0 to 40° C), relative humidity to
Input   80%.
  120/240 V, 50/60 Hz, 350 VA   Storage:
      -40 to +150° F (-40 to +65° C)
Output   Temperature Coefficients:
  Current Ranges:   ±0.05% of applicable accuracy
  5 mA, 50 mA,500 mA, 5 A (dc)   specifications per degree Celsius of resistance
  Open-Circuit Test Voltage:   range.
  30 Vdc    
  Rating:

Displays

  Continuous use on all ranges   Two high-temperature, 0.7 in. (18 mm), liquid-
  Resistance Measurement Inputs   crystal, 31/2-digit displays showing 1999 at full
  Two isolated high-impedance inputs, each with   scale. Update rate is approximately three times
  separate range control and protection provided   per second.
  for flashover caused by inductive kickback.    
  Ranges

Dimensions

  Accuracy: ±0.5% reading, ±0.5% full scale   Instrument
  (when current has stabilized).   11" (H) x 16" (W) x 10.5" (D)
  Overrange:   280mm (H) x 406mm (W) x 267mm (D)
  Lead number one displayed with all other digits   Transport Case
  blanked.   13" (H) x 20" (W) x 21" (D)
      330mm (H) x 508mm (W) x 533mm (D)
 
Nominal
(ohms)
Resolution
(ohms)
Maximum Display
(ohms)
2m 0.001m 1.999m
20m
200m
0.01m
0.1m
19.99m
199.9m
2
20
0.001
0.01
1.999
19.99
200 0.1 199.9
2000 1.0 1999
   
 

Weight

    Instrument:
    Net 40 lb (18 kg)
    Shipping:
    66 lb (30 kg)
     
     

Features and Benefits
  • Direct digital reading saves time, no balancing is required.
  • Built-in discharge circuit safely discharges the specimen when test is completed, if lead accidentally disconnects or if power is lost.
  • Electromechanical safety indicator gives a visual indication of a charged or discharged specimen, even if
    power to the instrument is lost.
  • Two independent measuring channels allow simultaneous testing of primary and secondary windings
    or measurement of two phases at a time.
  • The sensitive surge detection circuitry monitors the contact operation of on-load tap-changers for the proper make-before-break sequence. If an open circuit condition exists, the instrument shuts down immediately.
  • High-accuracy, four-terminal bridge: no lead compensation required.
  • Electronically generated and regulated current supply overcomes high-inductance transformers quickly,
    allowing fast measurements to be taken. Display of measurement occurs only after test current stabilizes.
  • Wide resistance range allows heat-run testing of many transformer types.
  • Lightweight and portable, the Transformer Ohmmeter is ideal for use in shop or substation environments.
  • Over-temperature protection provides automatic current shutdown and LED indication to prevent instrument damage.
  • Instrument and accessories come in a foam-lined transport case.


 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008