Model VCM100
               Oil Test Set Calibration Meter

You are here:   VCM100 Oil Test Calibration Meter
Navigation:   Oil Test Equipment Index > Megger Product Index >

You are here:

 

Description
The VCM100 is a calibration meter suitable for verifying the calibration of oil test sets

 

 


The VCM100 is a calibration meter suitable for verifying the calibration of oil test sets. The meter will enable the high voltage output to be checked, traceable to national
standards, and is suitable for all recent laboratory models of Foster oil dielectric strength test sets such as the OTSAF series and the OTS auto and semi automatic series.

The calibration meter fits in the oil test set chamber in place of a standard vessel. The design ensures that the load to the transformer is similar to the load during an oil
dielectric strength test. The voltage indication is viewed on an analogue display marked from 0 to 100 kV with 2 kV divisions. The scale also shows pass tolerance bands to enable a quick assessment of the accuracy to be made. The meter is supplied in a protective bag.
 

Operation
New versions of the OTSAF are programmed with a test sequence suitable for using the VCM100. This sequence
causes the output of the oil test set to ramp up from 0 kV to the maximum voltage value, pausing at each      10 kV point for 10 seconds to allow the calibration to be checked.

Use with individual models of Foster oil test set;
 

1. OTS60
Use either ‘manual’ by setting 10 kV, 20 kV......60 kV in turn or use the slowest ramp rate of 0,5 kV/sec.

2. OTS60 auto
Use either ‘manual’ by setting 10 kV, 20 kV......60 kV in turn or use the ASTM D1816 which ramps slowly at 0,5 kV/sec.

3. OTS60AF
Use either the calibrate option or the ‘Withstand’ (Proof) program by setting 10 kV, 20 kV......60 kV in turn or use the ASTM D1816 which ramps slowly at 0,5 kV/sec.

 

4. OTS75 auto
Use either ‘manual’ by setting 10 kV, 20 kV......75 kV in
turn or use the ASTM D1816 which ramps slowly at 0,5
kV/sec.

5. OTS80AF
Use either the calibrate option or the ‘Withstand’ (Proof) program by setting 10 kV, 20 kV......80 kV in turn or use the ASTM D1816 which ramps slowly at 0,5 kV/sec.

6. OTS100AF
Use either the calibrate option or the ‘Withstand’ (Proof) program by setting 10 kV, 20 kV......100 kV in turn or use the ASTM D1816 which ramps slowly at 0,5 kV/sec.
 
 
Specification  
Panel meter scaling 0 - 100 kV in 2 kV divisions
Accuracy ±3% of full scale
Temperature Range  
  Operational: 0°C to 40°C
  Storage: -30°C to +70°C
Humidity Range  
  Operational: 80% RH at 40°C
  Storage: 93% RH at 40°C
Safety The meter is only approved for use with Megger oil test sets.
Dimensions 198 mm x 235 mm x 102 mm
Weight 2.4 kg

 

Ordering Information
 
Order Code Description
VCM100 Oil Test Set calibration Meter.

 

Included Accessories
Order Code Description
6420-094 Carrying case
6172-044 Instruction Card
  Certificate of calibration


 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008