Product Specifications

Main Output
The main output on the unit has four taps, allowing the selection of output voltages up to 240V and output currents up to 100A. The output is switched on and off by illuminated pushbuttons, and the current is set using the main control knob on the front panel. All ranges are continuously variable from zero.
 
Range Continuous 5 minutes 1 minute
10V 33A 67A 100A
35V 10A 20A 30A
100V 3A 6A 10A
240V 1A 2A 3A
240V DC 1A 2A 3A

The above intermittent on times must be followed by an off time of 15 minutes, and are based on an ambient temperature of 25°C.

Auxiliary AC and DC Outputs
A switched, isolated auxiliary DC supply is available to power the relay under test. The output is protected by a fuse and electronic fold back current limiting circuit.

DC stabilized output

24V 1.04A
48V 0.52A
60V 0.42A
110V 0.23A
220V 0.11A

The auxiliary AC output is isolated and fuse protected.

Fixed AC output
  110Vac 300mA

Metering
The output is metered by a digital true RMS system with a memory ammeter - whenever the timer stops and the output is switched off, the current reading is held on the display. The metering range is selected by a rotary-switch.

Range Resolution Trip current Accuracy
2.000A 0.001A 2.2A ±0.5%rdg+5d
10.00A 0.01A 11A ±0.5%rdg+5d
20.00A 0.01A 22A ±0.5%rdg+5d
100.0A 0.1A 110A ±0.5%rdg+5d

An electronic current trip is automatically set to 110% of full scale of the selected metering range to protect the device under test.

Supply Requirements
115V±10% 50/60Hz 1ph 1100VA max
230V±10% 50/60Hz 1ph 1100VA max

The correct range is automatically selected by the unit.

RS232 Port
An RS232 port is provided to allow connection to a PC or a printer. ADMlog software is available as an optional extra to log results from the 100ADM mk2 and transfer them to a spreadsheet.

T&R Link
The T&R Link output allows a T&R DVS3 mk2 voltage source to phase lock to the 100ADM mk2 current.

Timing System
The timing system on the 100ADM is very flexible, allowing a wide range of protective devices to be timed.

Timing System
Range 0-999.999s
Resolution 1ms
Accuracy 0.01% rdg +2d (all except current operated mode)
  0.01% rdg +4d (current operated mode)

The contact circuit has an open circuit voltage of 24Vdc and a short circuit current of 20mA. Each contact circuit will auto-select for normally open or normally closed contacts. A DC voltage of 24-240Vdc may also be used to trigger either timer channel. The output is automatically switched off at the end of the test to safeguard the relay under test.

The following functions are provided:

Functions
Mode Timer Start Timer Stop
Internal start Press ‘ON’ Contact 1
Single contact Contact 1 Contact 1
Dual contact Contact 1 Contact 2
Current operated Current > 20% of range Current < 20% of range

Pulse mode is used for setting the current level in devices sensitive to heating. In this mode current is injected for 400ms and the current recorded.

The output is automatically switched off at the end of the test to safeguard the relay under test in internal start, dual contact, and current operated mode. The output switches off after the first change of contact in single contact mode to allow the testing of auto-reclose devices.

Temperature Range
Storage -20°C to 60°C
Operating 0°C to 45°C

Dimensions
340mm x 230mm x 330mm Including carrying handle

Weight
20.7kg

Protection and Safety
The unit is protected by electronic over current trips on the outputs, fuses on the contact inputs, and fuses on the mains input and regulator. The auxiliary AC output is fuse protected, and the stabilized DC output is protected by an electronic trip and fuse. An earth terminal is provided for connection to a local earth.

The unit is designed to comply with BSEN61010, and is CE marked.
 

100ADM Accessories

 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008