Macey's Electrical Logo

T and R Test Equipment logo

High Current Test System

200A-3PH/E/ED 3-Phase Current Injection

 

You are here:

Models 200A-3PH/E and 200A-3PH/ED Specifications

Navigation:

High Current Tester Index >  T&R Test Equipment Index > 200A-3PH Features

 
Product Specifications

Main Output
The units have three independently controlled outputs, one for each phase. The output is switched on and off by illuminated pushbuttons, and the current is set using the three control knobs on the front panel. All ranges are continuously variable from zero.
 
Range Continuous 5 minutes 1 minute  
5V 50A 100A 200A  

The above intermittent on times must be followed by an off time of 15 minutes, and are based on an ambient
temperature of 25°C.

Auxiliary AC Outputs
A switched, isolated auxiliary 240V 50mA AC supply is available to power auxiliary control circuits. The output is
protected by a fuse.

Analogue Metering: 200A-3PH/E
The output on the 200A-3PH/E is metered by a digital true RMS system with analogue meters. The range for each channel is selected by a switch on the front panel.

Range Accuracy  
50A 1% of full scale  
100A 1% of full scale  
200A 1% of full scale  

Digital Metering: 200A-3PH/ED
The output on the 200A-3PH/ED is metered by a digital true RMS system with a 3.5 digit LED display. The range
for each channel is independently selected for each channel by a switch on the front panel.
 
Range Resolution Trip Current Accuracy  
10A 0.01A 11.5A ±0.6% of reading +6 digits  
20A 0.01A 23A ±0.6% of reading +6 digits  
100A 0.1A 115A ±0.6% of reading +6 digits  
200A 0.1A 230A ±0.6% of reading +6 digits  

An electronic current trip is automatically set to 115% of full scale of the selected metering range to protect the device under test.

Supply Requirements
400V+14%-6% 50/60Hz  3-phase 4 wire 3300VA max
A delta-star transformer is available as an optional accessory for operation from a 3 wire supply.

Temperature Range
Storage Temperature:  -20°C to 60°C
Operating Temperature: 0°C to 45°C

Dimensions
200A-3PH/E:   315mm x 550mm x 300mm
200A-3PH/ED: 315mm x 550mm x 300mm

Weight
200A-3PH/E:   35kg
200A-3PH/ED: 35kg

Timing System
The timing system on the 200A-3PH/E/ED is very flexible, allowing a wide range of protective devices to be timed.

Range 0 to 999.999s    
Resolution 1ms    
Accuracy 0.01% of reading +1 digit (all except current operated mode)  
  0.01% of reading +3 digits (current operated mode)  

The contact circuit has an open circuit voltage of 24Vdc and a short circuit current of 300mA. The contacts may be connected to volt-free contacts or contacts connected to a DC voltage system (220Vdc maximum).

The following functions are provided:
Mode Timer Start Timer Stop  
Normally Open Press 'ON' Contact closes  
Normally Closed Press 'ON' Contact opens  
Current Operated Current >20% of range Current<20% of range  
OFF Timer inoperative Timer inoperative  
The output is automatically switched off at the end of the test to safeguard the relay under test.

Protection and Safety
The 200A-3PH/ED is protected by electronic over current trips on the outputs, fuses on the contact input, the mains input and regulators.

The 200A-3PH/E is protected by fuses on the contact input, the mains input and regulators.

The auxiliary AC output is fuse protected on both units. An earth terminal is provided for connection to a local
earth.

The unit is designed to comply with BSEN61010, and is CE marked.

Accessories Supplied with Unit
Operating manual, mains lead, spare fuse set.

Optional Accessories
200AL/3PH Output lead set.

Optional Lead Set specifications
The 200AL/3PH lead set includes the following items:

 
  • 6ea.  5meter 25mm2 200A leads terminated in M10 fork crimps.
  • 1ea.  5meter 2 core auxiliary lead terminated in 4mm plugs.
  • 1ea.  5meter 2 core auxiliary lead terminated bare ends.

The lead set is supplied in a reinforced plastic wallet.

 
200A-3PH Product Features

 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Friday, 03 October 2008