Macey's Electrical Logo

T and R Test Equipment logo

High Current Test System

200ADM-P Current Injection System

with Phase Shift

You are here:

Model 200ADM-P Specifications

Navigation:

T&R Test Equipment Index > T&R 200ADM-P Features >  200ADM-P Specifications

 
Specifications
 

Main Output
The main output on the unit has four taps, allowing the selection of output voltages up to 240V and output currents up to 200A.

 

 

Current

Output @230V

Range

Continuous

5 min*

1 min*

6 sec**

O/CV

Load V

10V

33A

67A

100A

200A

10.6V

8.7V@100A

35V

10A

20A

30A

-

36V

32V@30A

100V

3A

6A

10A

-

108V

99V@10A

240V

1A

2A

3A

-

276V

259V@3A

240Vdc

1A

2A

3A

-

 

Note:
*Off time of 15 minutes. On times based on an ambient temperature of 25°C.
**6 second intermittent ratings available with 230V supply.
  Protection: over current trip, duty cycle trip, thermal monitoring.
 

Current Limit Mode
The main output has a current limit mode that gives very fine control of output currents up to 10A. It also allows fine current control into very low impedance loads such as digital relays.

 

 

Current

Output @230V

Range

Short Circuit

Continuous

5min

2min

O/CV

Load V

10V

10A

3A

6A

10A

8.6V

5V@6A

35V

3A

1A

2A

3A

29V

132V@30A

100V

1A

0.3A

0.6A

1A

88V

99V@10A

240V

0.3A

0.1A

0.2A

0.3A

224V

259V@3A

 
Auxiliary DC Output
 

Range

Maximum A

Continuous Rating

12-60V

1A

25W

60-220V

0.23A

25W


Protection: current limit
 
Phase-shifting AC Output
 

 

Maximum Output Voltage

Current

Current

Range

No Load

Full load

Continuous

5 min on/15 min off

0-130V

144V

125V

0.23A

0.46A

0-260V

288V

250V

0.11A

0.23A

0-6V

6.6V

5V

5A

10A


Frequency range: 45—100Hz
Phase angle: 0—±180°
Protection: current limit and electronic trip.
 
Metering
The output is metered by a digital true RMS system with a single cycle capture memory ammeter—whenever the timer stops and the output is switched off, the current reading is held on the display. The RMS value of a single cycle can be captured. A current trip is set to 110% of full scale of the selected metering range.
 

Range

Resolution

Trip
current

Accuracy

Acquisition
time

5.000A

0.001A

5.5A

±0.5% rdg±5d

20ms

20.00A

0.01A

22A

±0.5% rdg±5d

20ms

50.00A

0.01A

55A

±0.5% rdg±5d

20ms

200.0A

200.0A

220A

±0.5% rdg±5d

20ms

 
Auxiliary Metering Inputs
 

Setting

Range

Resolution

Accuracy

Vdc/ac rms

300.0V

0.1V

±0.7% rdg±5d

Idc/ac rms

5.000A CF<3
9.999A CF<1.5

0.001A

±0.7% rdg±5d

Phase

-179.9° to +180.0°

0.1°

±3°

Frequency

40-100Hz

0.01Hz

±0.02% rdg±2d


Protection: fuse on current input
 
Timing System
 
Range 0-999.999s/9999.99s/99999.9s autoranging
Resolution 1/10/100ms
Accuracy 0.01%rdg+2d (+4d current operated mode)
Contact o/c 24V
Contact s/c 20mA
Vdc 24—240V
 
Each contact circuit will auto-select for normally open or normally closed contacts. A DC voltage of 24—240Vdc may also be used to trigger either timer channel. Contact state is shown by an LED.
 
Supply Requirements
 
115V/230V ±10% auto-selecting 50/60Hz 1ph 2300VA max.
 
Safety
 

An earth terminal is provided for connection to a local earth. The unit is designed to comply with BSEN61010 and is CE marked.

 
Temperature Range
 
Storage -20°C to 60°C
Operating0°C to 45°C
 
Dimensions
 
  Dimensions Weight
Standard unit 380mm x 314mm x 221mm 19.5kg
Pelicase unit 560mm x 456mm x 265mm 23.3kg
 
Cases and Options
 
Unit with Standard Aluminium Case Pelicase option
 
Pelicase option
 
T-R SDM200-P unit with standard aluminium case T-R 200ADM-P unit in Pelicase T-R 200ADM-P unit with Pelicase handle extended

 

Accles & Shelvoke| Aqua-Tronics | Arbiter Systems | Clare Instruments | Haefely | Hipotronics | HV Diagnostics | Megger | Tettex | T & R Equipment  
Home Page | High Current | High Voltage | Cable Fault | Oil Test | Transformer | Insulation 

 
Macey's Electrical Pty Ltd
ABN 17 344 601 468
Unit 1, 49 Gavenlock Road,  Tuggerah,  Sydney  Australia  2259

 

Phone: 61 2 4353 4644 

Mobile: 0412 678 925

Fax: 61 2 4353 4424

mailto:sales@maceyselectrical.com.au
 

Copyright: 1978 to 2007                                                   Last update: Wednesday, 10 December 2008